  1. Christophorou L G, Olthoff J K, Van Brunt R J. Sulfur hxafluoride and the electric Magazine, 1997, 13(5): 20⁃24. [Google Scholar]
  2. Pang Lei, Huang Jie & Zhang Junjie. (2023). Cause analysis of burning of 500kV GIS circuit breaker contacts in a powerplant. Energy engineering (4), 96–99. The DOI: 10.16189/j.ygc.2023.04.015. [Google Scholar]
  3. Du Jinzhi, Zhai Xiang & Xiong Zhonghao. (2021). Analysis and treatment of structural defects of 500 kV GIS isolation switch contacts. Rural electrification (03) : 63–64. DOI: 10.13882/j.carolcarrollnkiNCDQH.2021.03.020. [Google Scholar]
  4. Huang Mengdan. (2019). The GIS equipment heating mechanism and testing method (a master’s degree thesis, wuhan university of technology). https://kns.cnki.net/KCMS/detail/detail.aspx?dbname=CMFD202002&filename=1020735212.nh [Google Scholar]
  5. Liu Yuan, Yang Jinggang, Jia Yongyong, Song Siqi, Wu Bang & Li Junhao. (2019). GIS isolation switch contact detection technology based on vibration principle. High Voltage Technology (05), 1591–1599. DOI:10.13336/j.1003-6520.hve.20190430032. [Google Scholar]
  6. Xu Hang yao. (2018). The GIS touch hair tropical electrical inspection and condition assessment technologies (a master’s degree thesis, north China electric power university (Beijing)). https://kns.cnki.net/KCMS/detail/detail.aspx?dbname=CMFD201901&filename=1018241562.nh [Google Scholar]
  7. PangWenLong. (2020). Super high grade GIS latent fault mechanism and characteristics of research (a master’s degree thesis, wuhan university of technology). https://kns.cnki.net/KCMS/detail/detail.aspx?dbname=CMFD202102&filename=1021653087.nh [Google Scholar]
  8. Zhu Guanghe, Zhu Zhiqiang, Yuan Yiping. Fault upper limit evaluation algorithm of GIS equipment based on time series model and deep learning [J/OL]. Journal ofjilin university (engineering science) : 1–8 [2023-09-20]. DOI: 10.13229/j.carolcarrollnkiJDXBGXB.20230307. [Google Scholar]
  9. Ma Jiaqi, Wang Fenghua, Sheng Gehobart, Qian Yong, Zhang Jianlei, Wang Feng & Liu Yong... Fault diagnosis of GIS isolation switch based on synchronous squeeze transform and deep transfer learning. Electric power automation equipment. DOI: 10.16081/j.pae.202304019. [Google Scholar]
  10. Feng Yang, Zhou Lei, Ma Quanfu et al. Detection GIS partial discharge of miniaturization, multi-band antennas [J/OL]. China electric power, 2023 (4) : 167–174 [2023-09-20]. http://kns.cnki.net/kcms/detail/11.3265.TM.20230427.1318.022.html [Google Scholar]